Overview
If you’re off-grid and shore power isn’t available, a portable generator is your next best option to charge the caravan. The Victron MultiPlus-II Inverter/Charger will automatically detect the generator input and begin charging the battery — but to avoid generator stalling, you must set the system up correctly using Power Assist.
1. Generator Type: Bonded or Floating Neutral
The Victron MultiPlus-II Inverter/Charger is designed to work with both bonded and floating neutral generators.
- The system automatically detects the generator’s AC input type and adjusts its internal configuration to ensure:
- Proper grounding
- Safe operation of RCDs (Residual Current Devices, also known as ground fault protection)
There’s no need to manually bond the neutral or modify your generator — the system handles it internally for safe and correct operation.
However, if a fault is shown (e.g. no earth or RCD tripping), this may indicate:
- A wiring issue with the generator plug
- An incompatible generator model or poor grounding on the generator frame
When in doubt, consult your Harvok technician or the Victron MultiPlus-II manual.
2. Why Generators Stall — and How to Prevent It
Generators may stall if the caravan draws more current than the generator can supply.
Example:
A 3000VA (3kVA) generator typically supplies up to 12 Amps. If your van tries to pull 15A or more (e.g. with air conditioning + microwave), the generator may overload and shut off.
3. Victron Power Assist: Seamless Support
The Power Assist feature in your Victron MultiPlus-II prevents stalling by intelligently blending generator and battery power.
How it works:
- You set a safe AC input limit (e.g. 11A for a 3kVA generator).
- The inverter will only draw 11A from the generator.
- If you use more than 11A in the van (e.g. 20A), the inverter supplies the extra 9A from the battery.
- This prevents overload while still powering your appliances.
4. How to Set the Generator Input Limit (AC Input)
Caution: Only adjust these settings if you’re confident, or consult a Harvok technician.
To change the AC input limit:
- Go to your Victron Digital Multi Control panel.
- Use the rotary knob to select a current limit (e.g. 10A or 11A).
- The new limit controls how much current the system will draw from the generator.
5. General Setup Instructions
To charge your van with a generator:
- Start the generator and let it warm up (2–3 minutes).
- Plug a 15A power lead from the generator into the caravan’s driver-side power inlet.
- Ensure the AC Input Limit is correctly set.
- The Victron inverter will switch to charging mode and begin supplying 240V AC to appliances.
- If more power is needed than the generator can provide, Power Assist will supplement with battery power automatically.
Generator Sizing Recommendation
- Minimum Capacity: 3000VA (3kVA) recommended
- Must output pure sine wave, 230–240V AC, 50Hz
Technical Reference
- Inverter Model: Victron MultiPlus-II 48/3000/35-50 230V
- Max Charge Rate: 30A at 48V
- Compatible Input: Shore power or neutral bonded generator
📘 Victron MultiPlus-II Inverter/Charger Manual (AU Model)📘 Victron Digital Multi Control – Operating Manual